Arrhenius Equation Calculator — k = A exp(−Ea/RT)

Enter the pre-exponential factor A, the activation energy Ea in kJ/mol, and two absolute temperatures. The rate constant is k = A exp(−Ea / RT) with R = 8.314 J/(mol·K), so Ea is converted from kJ/mol to J/mol internally. The page also reports the ratio k2/k1 = exp[−(Ea/R)(1/T2 − 1/T1)] between T2 and T1. This is not a mechanism, an enzyme-kinetics fit, or a non-Arrhenius model.

Arrhenius parameters

Formulas

k = A exp(−Ea / RT)

k2 / k1 = exp[−(Ea / R) (1/T2 − 1/T1)]

Where k = rate constant, in the same units as A; A = pre-exponential factor; Ea = activation energy, entered in kJ/mol and converted to J/mol; R = 8.314 J/(mol·K); T, T1, T2 = absolute temperature, in kelvin.

R = 8.314 J/(mol·K), the value used in OpenStax Chemistry 2e for the Arrhenius equation. Ea is multiplied by 1000 to convert kJ/mol to J/mol.

A and k share units (for example both s⁻¹ for a first-order constant). The page does not convert those units.

The ratio uses only Ea and the two temperatures; it does not need A.

Checked examples

A = 1e13, Ea = 50 kJ/mol, T1 = 298 K: k = 1e13 × exp(−50000/(8.314×298)) = 17198. T2 = 310 K gives k2/k1 = 2.184.

A = 1e12, Ea = 75 kJ/mol, T1 = 300 K: k = 1e12 × exp(−75000/(8.314×300)) = 0.08727. T2 = 310 K gives k2/k1 = 2.638.

A = 1e11, Ea = 60 kJ/mol, T1 = 298 K: k = 3.0379. T2 = 308 K gives k2/k1 = 2.195.

Limits

A, Ea, T1, and T2 must all be greater than zero. Temperatures are kelvin, not Celsius. The model is a single Arrhenius line, not a change of mechanism with temperature. Not for: multi-step mechanisms with more than one activation energy; Michaelis–Menten or other enzyme rate laws; units in which A and k are not consistent with each other.

OpenStax Chemistry 2e — §12.5 Collision Theory.