PCB trace width from current and temperature rise (IPC-2221)
Enter the continuous current, allowed temperature rise, copper weight, and layer type. The tool returns the minimum trace width in mil and mm, cross-section area, and optionally resistance, voltage drop, and power loss for a given trace length. This is not a controlled-impedance calculator and does not account for nearby copper planes or forced airflow.
Current and thermal limits
Formulas
A = (I / (k × ΔT^0.44))^(1/0.725)
W = A / t
R = ρ × L / A × (1 + α × (T_op - 25))
V_drop = I × R
P_loss = I² × R
Where I = current, A; ΔT = temperature rise above ambient, °C; k = layer constant (0.048 external, 0.024 internal); A = copper cross-section area, mil²; t = copper thickness, mil (1.378 mil per oz/ft²); W = trace width, mil; ρ = copper resistivity, 1.7×10⁻⁶ Ω·cm; L = trace length, cm; α = copper temperature coefficient, 0.0039 /°C; T_op = operating temperature = ambient + ΔT, °C.
Checked examples
5 A, 10 °C rise, 1 oz external, no length → area 150.0 mil², width 108.9 mil (2.765 mm).
2 A, 10 °C rise, 1 oz external, 100 mm → 30.8 mil, R=0.0646 Ω, V_drop=0.1292 V, P=0.2583 W.
1 A, 10 °C rise, 1 oz internal (k=0.024) → 30.8 mil, same area as 2 A external.
Limits
Based on IPC-2221 Section 6.2 (formerly IPC-D-275), which covers currents up to 35 A, trace widths up to 400 mil, temperature rise 10–100 °C, and copper weights 0.5–3 oz/ft². The model assumes a trace on a thick board in still air at STP with no nearby copper planes or pours. Real boards with planes run cooler; this calculator is conservative (overestimates required width). Resistance, voltage drop, and power loss are calculated only when trace length > 0. Operating temperature = ambient + temperature rise. Copper resistivity 1.7×10⁻⁶ Ω·cm at 20 °C, temperature coefficient 0.0039 /°C. 1 oz/ft² = 1.378 mil = 35 µm. Not for: controlled-impedance or high-frequency trace design; traces with significant nearby copper pour or planes that alter thermal performance; forced-air or liquid-cooled boards; currents above 35 A (extrapolation beyond IPC-2221 data).
EngineeringFormula — PCB Trace Width Calculator (IPC-2221) and Altium — IPC-2221 Calculator for PCB Trace Current and Heating.