SPL Distance Calculator — Sound Level Change with Distance
Enter a known SPL at a reference distance and a target distance to get the predicted SPL at the target distance. Uses the inverse square law for a point source in free field: ΔSPL = 20 × log₁₀(d₁/d₂). This is not a room acoustics model and does not account for reflections, absorption, barriers, or directional sources.
Distance parameters
Formulas
ΔSPL = 20 × log₁₀(dist_ref / dist_target)
SPL_target = SPL_ref + ΔSPL
Where SPL_ref = sound pressure level at reference distance in dB; dist_ref = reference distance from source; dist_target = target distance from source; ΔSPL = change in SPL between reference and target in dB; SPL_target = predicted SPL at target distance in dB.
Based on inverse square law for a point source in free field: pressure ∝ 1/r, so SPL change = 20 × log₁₀(r₁/r₂).
Each doubling of distance reduces SPL by ≈6.02 dB; each halving increases by ≈6.02 dB.
Reference and target distances must use the same unit (ratio is unitless).
Checked examples
90 dB at 1 m → 83.98 dB at 2 m. Doubling distance: −6.02 dB.
90 dB at 1 m → 77.96 dB at 4 m. Two doublings: −12.04 dB.
100 dB at 3 m → 89.54 dB at 10 m. Ratio 3/10 = 0.3, 20×log₁₀(0.3) = −10.46 dB.
Limits
Reference SPL must be 0-200 dB. Both distances must be positive. Assumes free-field point source; real environments have reflections and absorption. Not for: Indoor or room acoustics predictions (reflections, reverberation); Barrier or obstacle attenuation; Directional source directivity patterns; Line source or area source propagation.
iCalculator Sound Pressure Level Distance Calculator and AIHA Sound Pressure Level Between Two Points.